Skip to content
eastbaycyber

CVE-2026-123890: VMware vCenter Authentication Bypass

CVSS · Critical
9.8
In CISA KEV
Yes
Published
Nov 21
Patch SLA & TriageVector: Network
Immediate (BOD 22-01 due 2026-11-23)

Active exploitation confirmed in CISA KEV.

Exposure:
Control:
CVSS v3.1 Blast RadiusScore: 9.8
Decode Vector & Sub-Scores →
CVE explainers 10 min read
Security Research Desk Source-checked
Auto-checked against the official CVE record · Human-reviewed after publishing · Updated 2026-11-21
⚠
CISA Known Exploited Vulnerability

Active exploitation confirmed in the wild. CISA added this to the KEV catalog on 2026-11-20. Federal agencies must patch by 2026-11-23.

Everything CISA added on 2026-11-20

▲ Escalation ViewOne CVE, briefed at three altitudes — skim the Brief, weigh the Impact, or work the Runbook. The way a SOC actually reads it.
CISOBrief · 30-second brief

TL;DR - CVE-2026-123890 is a CVSS 9.8 authentication bypass in VMware vCenter’s vmdir service. - Affected vCenter and VMware telco deployments require vendor-specific upgrades. vCenter 7.0 remediation must be confirmed with Broadcom. - CISA lists the flaw as actively exploited. Patch urgently and investigate potentially compromised instances.

CVE-2026-123890 is a critical VMware vCenter vulnerability affecting the VMware Directory Service (vmdir). The flaw can allow a remote, unauthenticated attacker to obtain an authenticated administrative session. It is listed in CISA’s Known Exploited Vulnerabilities catalog, so organizations should patch affected systems and investigate for compromise in parallel.

What Is the Root Cause?

The affected component is VMware Directory Service, commonly identified as vmdir, within vCenter. The weakness allows an alternate authentication path to bypass normal credential validation. Based on available technical reporting, successful exploitation can result in an authenticated administrative session, making this substantially more serious than a limited information disclosure or denial-of-service issue.

The precise implementation defect has not been publicly described in sufficient detail to state whether it is caused by an RPC validation error, an authorization condition, malformed request handling, or another specific code path. Broadcom’s advisory page returned a portal shell in the retrieved material, so the vendor’s full root-cause explanation could not be independently verified.

Defenders should not assume that disabling one authentication method or rotating passwords alone closes the vulnerability.

Supporting reporting places the vulnerable service’s RPC interface on TCP port 2012. That detail has moderate confidence because it comes from corroborating technical reporting rather than the fully rendered Broadcom advisory. Network reachability to that port should be treated as an exposure indicator, not proof that exploitation occurred.

AnalystImpact · assess the risk

What Happened?

CVE-2026-123890 is an authentication bypass vulnerability in the VMware Directory Service component of Broadcom VMware vCenter. The issue is classified as CWE-288, “Authentication Bypass Using an Alternate Path or Channel.” Available reporting indicates that a remote, unauthenticated attacker can obtain an authenticated session with administrator-level privileges.

The vulnerability was published on November 19, 2026, and added to CISA’s Known Exploited Vulnerabilities catalog on November 20, 2026. CISA’s remediation deadline is November 23, 2026. CISA does not identify ransomware use; the catalog value is Unknown, not “No.”

Field Value
CVE CVE-2026-123890
Product Broadcom VMware vCenter and related telco cloud products
Vulnerability type CWE-288 authentication bypass
CVSS 9.8 Critical
Attack vector Network-based remote exploitation
Authentication required None reported
Privileges required None reported
Patch available Yes for specified vCenter branches; vCenter 7.0 status requires Broadcom confirmation
CISA KEV status Yes
CISA added 2026-11-20
Remediation due date 2026-11-23

The NVD record does not provide a CVSS vector string. The attack-vector and access requirements above therefore reflect the published vulnerability description and supporting reporting rather than an independently reconstructed official vector.

Analyst’s Take: Treat this as an emergency management-plane exposure, not a routine patching queue item. CISA KEV status and reported exploitation justify investigating exposed instances while remediation proceeds, even though the supplied research does not confirm a public exploit or proof of concept.

For background on vulnerability terminology, see our malware glossary and CVE-2026-12183 analysis.

Who Needs to Act?

Organizations operating VMware vCenter should inventory every appliance and determine its exact product branch and build. The NVD-listed affected ranges and fixed releases are:

Product Affected versions Fixed version
VMware vCenter 9.1.x before 9.1.1.0200 9.1.1.0200
VMware vCenter 9.0.x before 9.0.2.0200 9.0.2.0200
VMware vCenter 8.0 before 8.0 U3m 8.0 U3m
VMware vCenter 5.x before 5.2.5 5.2.5
VMware Telco Cloud Platform 3.0, 4.x, 5.0.x, 5.1.x, 5.2 Consult Broadcom KB463116
VMware Telco Cloud Infrastructure 3.0 Consult Broadcom KB463116

Additional reporting indicates that vCenter 7.0 is affected, but no generally available public fix was identified in the supplied material. Customers with extended support should contact Broadcom for the applicable remediation. Do not infer that a patch for vCenter 8.0, an earlier authentication-bypass issue, or an adjacent VMware component remediates vCenter 7.0.

VMware Cloud Foundation 5.x is also identified in the supplied material as affected, with remediation associated with vCenter 8.0 U3m and SDDC Manager 5.2.5. Validate this mapping against the applicable Broadcom bill of materials before deployment.

Telco Cloud Platform and Telco Cloud Infrastructure customers should use Broadcom KB463116 and product-specific guidance rather than applying a vCenter patch outside the supported platform workflow.

Why Is the CVSS Score 9.8?

CVE-2026-123890 has a published CVSS base score of 9.8, rated Critical. The score is consistent with a remotely reachable vulnerability that does not require valid credentials and can produce high-impact administrative access. A successful attacker may be able to control vCenter-managed infrastructure indirectly by abusing the management plane.

The NVD response does not include a CVSS vector string. The following interpretation is therefore based on the published score, vulnerability description, and available reporting:

  • Network reachability: Exploitation is performed remotely against a network-accessible service.
  • No authentication: The attacker does not need valid credentials before exploitation.
  • No prior privileges: The attack does not require an existing vCenter account or role.
  • High confidentiality impact: Administrative access can expose infrastructure configuration, credentials, inventory, and operational data.
  • High integrity impact: An attacker with administrative control may alter vCenter configuration or managed resources.
  • High availability impact: Control of the virtualization management plane can affect the availability of hosted workloads.

CVSS is a prioritization measure, not a prediction of the exact business outcome in every environment. A vCenter instance isolated behind tightly controlled management networks may have lower practical exposure than an internet-reachable appliance, but isolation does not eliminate the need to patch. CISA KEV status and reported exploitation should drive emergency handling regardless of local compensating controls.

Has CVE-2026-123890 Been Exploited?

Yes. CVE-2026-123890 is listed in CISA’s Known Exploited Vulnerabilities catalog. That status confirms exploitation in the wild and should be treated as an incident-response signal, not merely a vulnerability-management score. CISA’s catalog does not establish that every vulnerable deployment was compromised, but it does establish that defenders should assume attackers may be targeting exposed instances.

Google Cloud Threat Intelligence reporting linked from the NVD describes exploitation of the vCenter zero-day by China-linked espionage activity. The supplied material associates the activity with a tool named BONESAW and reports targeting of vCenter 7.x and 8.x. These campaign details have moderate confidence compared with the KEV status, but they reinforce the requirement to investigate before and during remediation.

No verified public exploit repository or complete public proof of concept was identified in the supplied research. Rapid7 reportedly planned an unauthenticated vulnerability check that detects the flaw without exploiting it. No public patch-diff analysis or complete exploit PoC was confirmed.

The absence of public exploit code does not reduce urgency because operational exploitation is already reported.

ResponderRunbook · act now

Detection Guidance

Start by identifying all vCenter appliances, their exact versions, network exposure, and connections to VMware Cloud Foundation or telco cloud platforms. Prioritize appliances with internet exposure, inbound access from untrusted segments, or TCP 2012 reachable beyond the intended management plane.

A port scan result cannot confirm exploitation, but it can identify systems requiring immediate review.

Review vCenter authentication events, directory-service logs, administrative session creation, account changes, role assignments, certificate activity, inventory modifications, and unexpected changes to hosts, datastores, virtual machines, or networking. Preserve logs before rebuilding or rotating systems.

Because attackers may use valid-looking authenticated sessions after bypassing authentication, correlate events by source address, timestamp, user identity, session creation, and administrative action rather than searching only for failed logins.

Technical Notes

Use an approved vulnerability scanner or asset-management query to enumerate versions. A basic network check can help identify systems exposing the reported directory-service port:

nmap -Pn -p 2012 --open --reason <vcenter-or-management-subnet>

This check is not an exploit and does not establish that the service is vulnerable. Restrict scanning to authorized assets and compare results with the vCenter inventory.

A SIEM query should be adapted to the actual VMware log source and field names. The following generic example looks for successful administrative activity from unusual sources, account changes, and access to TCP 2012:

(
  destination.port = 2012
  OR event.action IN ("admin_session_created", "user_added", "role_changed",
                      "certificate_changed", "inventory_modified")
)
AND (
  source.ip NOT IN approved_vcenter_management_ranges
  OR user.name IN privileged_accounts
)

Also search for patterns such as vmdir, Directory Service, authentication, session, administrator, account creation, role assignment, and unexpected source addresses in vCenter and appliance logs. Exact filenames and message formats vary by vCenter release and logging configuration, so do not treat the absence of one literal string as evidence of safety.

If compromise is suspected, preserve vCenter logs, appliance logs, authentication records, network telemetry, identity-provider logs, and hypervisor audit data. Follow CISA’s forensic triage requirements referenced in the KEV guidance.

Coordinate containment and credential-reset decisions with incident responders because rotating credentials on a compromised management plane may not remove persistence or unauthorized configuration changes.

Remediation and Patching

Apply the fixed release corresponding to each affected branch:

  • Upgrade vCenter 9.1.x to 9.1.1.0200.
  • Upgrade vCenter 9.0.x to 9.0.2.0200.
  • Upgrade vCenter 8.0 to 8.0 U3m.
  • Upgrade vCenter 5.x to 5.2.5.
  • For vCenter 7.0, contact Broadcom Support for the applicable extended-support patch.
  • For VMware Telco Cloud Platform and VMware Telco Cloud Infrastructure, follow Broadcom KB463116 and the platform-specific supported upgrade path.
  • For VMware Cloud Foundation 5.x, validate the required vCenter and SDDC Manager versions against the applicable Broadcom bill of materials.

The exact upgrade workflow depends on the deployed appliance, lifecycle-management tooling, and platform bundle. Do not use an arbitrary package manager command or manually replace vmdir binaries.

Use the supported Broadcom upgrade mechanism for the product branch, verify pre-upgrade backups and snapshots according to vendor guidance, and confirm the resulting build after the upgrade.

Technical Notes

For an appliance managed through the vCenter Server Appliance Management Interface, administrators should use the supported VAMI or lifecycle-management workflow to select and install the applicable Broadcom update. A generic operational verification sequence is:

# Run on the vCenter appliance to record the installed version/build.
vpxd -v

# Confirm the reported build against the required fixed release:
# 9.1.1.0200, 9.0.2.0200, 8.0 U3m, or 5.2.5.

The command above verifies the installed vpxd build; it does not apply the patch. Use the product’s supported update workflow to install the release, then confirm the build and review update logs.

If immediate patching is impossible:

  1. Restrict vCenter management interfaces to trusted administration networks.
  2. Block unnecessary access to TCP 2012.
  3. Remove direct internet exposure.
  4. Apply only mitigations explicitly documented by Broadcom.
  5. Increase monitoring of authentication, administrative sessions, and configuration changes.
  6. Preserve relevant logs and network telemetry.

Network isolation is a temporary risk-reduction measure, not proof of remediation. Do not assume that firewalling TCP 2012 alone addresses every possible alternate path or channel.

After patching, conduct a compromise assessment. Review privileged sessions and configuration changes from at least the period beginning before public disclosure and extending through remediation.

Reset potentially exposed credentials, certificates, tokens, and service-account secrets based on incident-response findings. If unauthorized access or tampering is identified, follow organizational breach procedures and preserve evidence before rebuilding affected appliances.

References

  1. NVD: CVE-2026-123890
  2. Broadcom security advisory and vendor reference
  3. CISA Known Exploited Vulnerabilities Catalog
  4. Google Cloud Threat Intelligence reporting
  5. Rapid7 analysis of CVE-2026-123890
  6. Tuskira advisory

The vendor advisory and Broadcom KB463116 should take precedence over secondary reporting for exact build applicability, supported upgrade procedures, and product-specific mitigations. Where public sources do not provide a confirmed version or technical detail, defenders should treat the deployment as potentially affected until Broadcom or an authorized support channel confirms otherwise.

This article may contain affiliate links. We earn a commission on qualifying purchases at no extra cost to you.

Last verified: 2026-11-21

Disclaimer: This article may contain affiliate links. We earn a commission on qualifying purchases at no extra cost to you.